HF-12
HF-12, a popular choice among architects for a variety of institutional, industrial and commercial applications, is Agway’s most popular Hidden Fastener profile. With no visible fasteners, these 12” panels install easily and deliver the clean, sleek lines of contemporary surfaces,
Available in a range of gauges and a variety of standard and custom colours, HF-12 enables customers to specify the ideal combination of strength and aesthetics that optimize achievement of all project objectives.
Measurement Type
Profile Picture
1. Steel conforms to ASTM A653.
2. Section properties are in accordance with CSA-S136-07.
3. Values in row “S” are based on strength.
4. Values in row “D” are based on a deflection limit of 1/180 of the span.
5. Web crippling not included in strength values. See example calculation in notes to designer.
6. Oil canning may be present due to thickness and coverage. Oil canning is not a valid reason for rejection of this product.
7. Contact the sales department for stocked colours and gauges.
8. The load table contained on this data sheet was prepared by Dr. R.M. Schuster P.Eng. Professor Emeritus of Structural Engineering, University of Waterloo, Ontario, Canada.
1. Steel conforms to ASTM A653.
2. Section properties are in accordance with CSA-S136-07.
3. Values in row “S” are based on strength.
4. Values in row “D” are based on a deflection limit of 1/180 of the span.
5. Web crippling not included in strength values. See example calculation in notes to designer.
6. Oil canning may be present due to thickness and coverage. Oil canning is not a valid reason for rejection of this product.
7. Contact the sales department for stocked colours and gauges.
8. The load table contained on this data sheet was prepared by Dr. R.M. Schuster P.Eng. Professor Emeritus of Structural Engineering, University of Waterloo, Ontario, Canada.
Specifications
GAUGE | LENGTH | COVERAGE | ||
---|---|---|---|---|
MINIMUM | MAXIMUM | MINIMUM | MAXIMUM | |
22 | 18 | 10 | 540 | 12 |
GAUGE | LENGTH | COVERAGE | ||
---|---|---|---|---|
MINIMUM | MAXIMUM | MINIMUM | MAXIMUM | |
22 | 18 | 254 | 13.72 | 305 |
Section Properties
BASE STEEL THICKNESS |
WEIGHT G90 |
YIELD STRESS |
SECTION MODULUS |
DEFLECTION MOMENT OF INERTIA |
|
---|---|---|---|---|---|
in | psf | ksi | MID SPAN in 3 |
SUPPORT in 3 |
MID SPAN in 4 |
0.030 | 1.87 | 33 | 0.0903 | 0.132 | 0.0817 |
0.036 | 2.23 | 33 | 0.120 | 0.158 | 0.106 |
0.048 | 2.96 | 33 | 0.184 | 0.210 | 0.163 |
BASE STEEL THICKNESS |
MASS Z275 |
YIELD STRESS |
SECTION MODULUS |
DEFLECTION MOMENT OF INERTIA |
|
---|---|---|---|---|---|
mm | kg/m | MPa | MID SPAN x10 3 mm3 |
SUPPORT x10 3 mm3 |
MID SPAN x10 3 mm3 |
0.762 | 8.85 | 230 | 4.84 | 7.10 | 0..111 |
0.914 | 10.6 | 230 | 6.45 | 8.50 | 0.144 |
1.22 | 14.2 | 230 | 9..88 | 11.3 | 0.221 |