Diamond Rib
Agway’s Diamond Rib profile is one of our most popular and versatile lightweight profiles. Economical and easy to install, the Diamond Rib profile is the standard wall cladding for agricultural applications, and captures the classic barn look. For convenience and simplicity, these versatile panels can be installed vertically or horizontally on a wall, or as a roof panel and, once installed, are extremely weather resistant and virtually maintenance free. Available in a wide range of colours, Agway’s Diamond Rib profile, combined with available trims, vents, fasteners and other accessories, provides a complete cladding solution for any project.
Measurement Type
Profile Picture
1. Steel conforms to ASTM A653.
2. Section properties are in accordance with CSA-S136-07.
3. Values in row “S” are based on strength.
4. Values in row “D” are based on a
deflection limit
of 1/180 of the span.
5. Web crippling not included in strength values. See example calculation in notes to designer.
6. Contact the sales department for stocked colours and gauges.
7. The load table contained on this data sheet was prepared by Dr. R.M. Schuster P.Eng. Professor Emeritus of Structural Engineering, University of Waterloo, Ontario, Canada.
8. Plain or painted Galvalume sheets should not be used on Animal Confinement Buildings.
1. Steel conforms to ASTM A653.
2. Section properties are in accordance with CSA-S136-07.
3. Values in row “S” are based on strength.
4. Values in row “D” are based on a
deflection limit
of 1/180 of the span.
5. Web crippling not included in strength values. See example calculation in notes to designer.
6. Contact the sales department for stocked colours and gauges.
7. The load table contained on this data sheet was prepared by Dr. R.M. Schuster P.Eng. Professor Emeritus of Structural Engineering, University of Waterloo, Ontario, Canada.
8. Plain or painted Galvalume sheets should not be used on Animal Confinement Buildings.
Specifications
GAUGE | LENGTH | COVERAGE | ||
---|---|---|---|---|
MINIMUM | MAXIMUM | MINIMUM | MAXIMUM | |
30 | 24 | 16 | 540 | 36 |
30 | 22 | 16 | 480 | 30 |
GAUGE | LENGTH | COVERAGE | ||
---|---|---|---|---|
MINIMUM | MAXIMUM | MINIMUM | MAXIMUM | |
30 | 24 | 406 | 13.72 | 914 |
30 | 22 | 406 | 12.92 | 780 |
Section Properties
BASE STEEL THICKNESS |
WEIGHT G90 |
YIELD STRESS |
SECTION MODULUS |
DEFLECTION MOMENT OF INERTIA |
|
---|---|---|---|---|---|
in | psf | ksi | MID SPAN in 3 |
SUPPORT in 3 |
MID SPAN in 4 |
0.0120 | 0.64 | 33 | 0.0221 | 0.0202 | 0.0144 |
0.0135 | 0.71 | 80 | 0.0227 | 0.0203 | 0.0152 |
0.0180 | 0.93 | 33 | 0.0381 | 0.0361 | 0.0227 |
0.0240 | 1.22 | 33 | 0.0550 | 0.0498 | 0.0302 |
0.0300 | 1.51 | 33 | 0.0683 | 0.0637 | 0.0637 |
BASE STEEL THICKNESS |
MASS Z275 |
YIELD STRESS |
SECTION MODULUS |
DEFLECTION MOMENT OF INERTIA |
|
---|---|---|---|---|---|
mm | kg/m | MPa | MID SPAN x10 3 mm3 |
SUPPORT x10 3 mm3 |
MID SPAN x10 3 mm3 |
0.305 | 3.11 | 230 | 1.19 | 1.09 | 0.0196 |
0.343 | 3.46 | 550 | 1.22 | 1.09 | 0.0207 |
0.457 | 4.52 | 230 | 2.04 | 1.94 | 0.0309 |
0.610 | 5.94 | 230 | 2.96 | 2.68 | 0.0412 |
0.762 | 7.36 | 230 | 3.67 | 3.42 | 0.0514 |